Class of Trunks (COT)

The Class of Trunk (COT) defines the switching technology parameters for call processing. Each trunk is assigned to a specific COT with multiple parameters. In this example, they are used as follows:

DISPLAY-COT:COTNO=3;
H500: AMO COT STARTED
   COT: 3 INFO: anynode
   DEVICE: INDEP SOURCE: DB
   PARAMETER:
        CALL IF USER HANGS UP IN CONSULTATION CALL RCL
        TRUNK CALL TRANSFER XFER
        TRUNK SIGNALING ANSWER ANS
        CALL EXTEND FOR BUSY, RING OR CALL STATE CEBC
        NETWORKWIDE AUTOMATIC CALLBACK ON BUSY CBBN
        NETWORKWIDE AUTOMATIC CALLBACK ON FREE CBFN
        NETWORKWIDE CALL FORWARDING PERMITTED FWDN
        NETWORKWIDE FORWARDING NO-ANSWER FNAN
        DON'T RELEASE CALL TO BUSY HUNT GROUP BSHT
        END-OF-DIAL FOR BLOCK IS SET BLOC
        SEND NO NODE NUMBER TO PARTNER LWNC
        CONNECTION TO ROUTE OPTIMIZATION NODE ROPT
        INCOMING CIRCUIT FROM SYSTEM WITHOUT LCR NLCR
        TSC-SIGNALING FOR NETWORKWIDE FEATURES (MANDATORY) TSCS
        USE DEFAULT NODE NUMBER OF LINE DFNN
        NO LOCAL HOLDTONE, HOLDTONE FROM REMOTE SYSTEM NLHT
        INCOMING CIRCUIT FROM SYSTEM WITHOUT LCR (DATA) NLRD
        PIN NETWORKWIDE POSSIBLE PINR
        SEND NO BILLINGELEMENTS SNBE
        DONT SEND DIV_LEG OPERATIONS, BASED ON DSS1 AND QSIG DSDL
        SUPPRESS SIGNALING OF CDR-E SPECIFIC MESSAGES NCDR
        LAST REDIRECTING NUMBER IS SEND TO PHONEMAIL LRPM
        NO FLAG TRACE NOFT
        NPI ISDN, OUTGOING CALL NPIS
        NO OUTGOING CALLTRANSFER INFOS ( REMOTE HOLD/ECT) NOCT
        INTERNAL DIAL TONE DTNI