Common Gateway Board (CGWB)

The AMO CGWB (Common Gateway Board) is responsible for configuring gateway-specific parameters. The following parameters and settings are applied in this deployment:

DISPLAY-CGWB:LTU=99,SLOT=5;
H500: AMO CGWB STARTED
------------------------------------------------------------------------------
| CGW BOARD DATA |
------------------------------------------------------------------------------
| HG3550 |
------------------------------------------------------------------------------
| LTU = 99 SLOT = 5 SMODE = NORMAL POOLNO: 0 |
------------------------------------------------------------------------------
  GLOBAL DATA AND ETHERNET INTERFACE DATA - CONFIGURABLE VALUES:
  --------------------------------------------------------------
  IPADR = 10 .8 .242.112 TCPP = (4060)
  NETMASK = 255.255.255.0 VLAN = NO (NO)
  DEFRT = 10 .8 .242.1 (0.0.0.0 = NOT CONFIGURED)
  BITRATE = (CHECK OS) VLANID = 0 (0)
  PATTERN = 213 (213) TLSP = 4061 (4061)
  TRPRSIP = 60 (0) TRPRH323 = 0 (0)
  TRPRSIPQ = 0 (0) TPRH323A = 0 (0)
  DNSIPADR = 10 .8 .251.103 SIPTCPP = 5060 (5060)
  DNSIPADR2 = 0 .0 .0 .0 SIPTLSP = 5061 (5061)
  USEWANIF = NO (NO)
  WPUBIP = 0 .0 .0 .0
  ASC DATA - CONFIGURABLE VALUES:
  -------------------------------
  TOSPL = 184 (184) TOSSIGNL = 104 (104)
  UDPPRTLO = 29100 (29100) UDPPRTHI = 30099 (30099)
  T38FAX = YES (YES) REDRFCTN = NO (YES)
  RFCFMOIP = YES (NO) RFCDTMF = YES (YES)
  PRIO1 : CODEC = G711A VAD = NO RTP-SIZE = 20
  PRIO2 : CODEC = G711U VAD = NO RTP-SIZE = 20
  PRIO3 : CODEC = NONE VAD = NO RTP-SIZE = 30
  PRIO4 : CODEC = G729 VAD = NO RTP-SIZE = 30
  PRIO5 : CODEC = G729A VAD = NO RTP-SIZE = 30
  PRIO6 : CODEC = NONE VAD = NO RTP-SIZE = 20
  PRIO7 : CODEC = G729AB VAD = YES RTP-SIZE = 20
  PRIO8 : CODEC = G722 VAD = NO RTP-SIZE = 20
  PRIO9 : CODEC = OPUS VAD = NO RTP-SIZE = 20
  ...
  ...
  DSP CONFIGURATION DATA
  ----------------------
  JITBUFD = 60 (60) (PARAMETER IS NOT USED ANYMORE)
  JB DATA - CONFIGURABLE VALUES:
  ------------------------------
  JBMODE = 2
  AVGDLYV = 40 (40)
  MAXDLYV = 120 (120) MINDLYV = 20 (20)
  PACKLOSS = 4 (4)
  AVGDLYD = 60 (60) MAXDLYD = 200 (200)
AMO-CGWB -111 CONFIGURATION OF HG3500 BOARD